Regulatory Compliances

Complies with the following EU directives

Radio Equipment Directive (2014/53/EU) only applies to devices containing radio module EM05-G.

No

Short Name

2014/35/EU

Low Voltage Directive (LVD)

2014/53/EU

Radio Equipment Directive (RED)

2014/30/EU

Electromagnetic Compatibility (EMC)

2011/65/EU

Restriction of the use of certain hazardous substances in electrical and electronic equipment Directive (RoHS2)

2015/863/EU

Amendment to Annex II in Directive 2011/65/EU regards the list of restricted substances (RoHS3)

References of standards applied

Standard

Reference

Issue

EN 18031-1

Common security requirements for radio equipment - Part 1: Internet connected radio equipment

2024

EN 55032

Electromagnetic compatibility of multimedia equipment - Emission Requirements

2015+A11:2020+A1:2020

EN 55035

Electromagnetic compatibility of multimedia equipment - Immunity requirements

2017+A11:2020

EN (IEC) 61000-3-2

Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions

2014 2019+A1:2021

EN 61000-3-3

Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems

2013 2013+A2:2021+AC:2022

EN 61000-4-2

Electromagnetic compatibility (EMC). Testing and measurement techniques. Electrostatic discharge immunity test

2009

EN 61000-4-3

Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

2006+A1:2008+A2:2010

EN 61000-4-4

Electromagnetic compatibility (EMC) - Part 4-4 : Testing and measurement techniques - Electrical fast transient/burst immunity test

2012

EN 61000-4-5

Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

2014+A1:2017

EN 61000-4-6

Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

2014+AC:2015

EN 61000-4-8

Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test

2010

EN IEC 61000-4-11

Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests

2004+A1:2017

EN 301 489-1 (module)

ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility

V2.2.3

EN 301 489-52 (module)

ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for Cellular Communication User Equipment (UE) radio and ancillary equipment; Harmonised Standard for ElectroMagnetic Compatibility

V1.2.1

Draft EN 301 489-19 (module)

ElectroMagnetic Compatibility (EMC) standard for radio equipment and services - Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band (ROGNSS) providing positioning, navigation and timing data

V2.2.0

ETSI EN 301 908-1 (module)

IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 1: Introduction and common requirements Release 15

V15.1.1

ETSI EN 301 908-2 (module)

IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment (UE)

V13.1.1

ETSI EN 301 908-13 (module)

IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE)

V13.2.1

EN 303 413 (module)

Satellite Earth Stations and Systems (SES) - Global Navigation Satellite System (GNSS) receivers - Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands - Harmonised Standard for access to radio spectrum

V1.2.1

EN IEC 62311 (module)

Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz – 300 GHz)

2020

EN 62368-1

Safety requirements: Audio/video, information and communication technology

2014+A11:2017

FCC PART 15 VERIFICATION STATEMENT

WARNING

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

May Contain transmitter module:

  • XMR2021EM05G

  • RYK-WHFQ262ACNIBT

ICES-003 ISSUE 7 VERIFICATION STATEMENT

CAN ICES3(A)/NMB3(A)

This device complies with CAN ICES-003 Issue 7 Class A. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme CAN ICES-003 Issue 7 Class A. Le fonctionnement est soumis auxdeux conditions suivantes : (1) cet appareil ne doit pas causer d’interférences nuisibles et (2) cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant opération indésirable.

May Contain transmitter module:

  • 6158A-FQ262ACNIBT

  • 10224A-2021EM05G